Designed to work with Apollo's AlarmSense detectors, call points, sounders and beacons, C-TEC's powerful range of LPCB-certified two-wire CFP AlarmSense fire panels are easy-to-install and very cost-effective.
LPCB certified to EN54-2/4, C-TEC's CFP two-wire 2 zone AlarmSense fire panel is designed to work with Apollo's AlarmSense range of detectors, call points, sounders and visual indicators. Most conventional fire systems work with two pairs of wires per zone: one pair for detection devices; the other for alarm devices. By using different voltage bands for... LPCB certified to EN54-2/4, C-TEC's CFP two-wire 2 zone AlarmSense fire panel is designed to work...
LPCB certified to EN54-2/4, C-TEC's CFP two-wire 4 zone AlarmSense fire panel is designed to work with Apollo's AlarmSense range of detectors, call points, sounders and visual indicators. Most conventional fire systems work with two pairs of wires per zone: one pair for detection devices; the other for alarm devices. By using different voltage bands for... LPCB certified to EN54-2/4, C-TEC's CFP two-wire 4 zone AlarmSense fire panel is designed to work...
LPCB certified to EN54-2/4, C-TEC's CFP two-wire 8 zone AlarmSense fire panel is designed to work with Apollo's AlarmSense range of detectors, call points, sounders and visual indicators. Most conventional fire systems work with two pairs of wires per zone: one pair for detection devices; the other for alarm devices. By using different voltage bands for... LPCB certified to EN54-2/4, C-TEC's CFP two-wire 8 zone AlarmSense fire panel is designed to work...
Can be used to repeat the functions of a master CFP standard or AlarmSense 2-8 zone fire panel at remote parts of site (e.g. all potential fire service entrances). Up to 8 repeaters per CFP master. Includes its own Mains power supply that requires its own standby battery supply. Provides the user with access to all AL1 and AL2 functions.... Can be used to repeat the functions of a master CFP standard or AlarmSense 2-8 zone fire panel at...
A high-quality lockable double pole Fire Alarm Control Panel Mains Keyswitch. Allows the Mains supply to a fire alarm panel to be switched on or off in accordance with BS 5839-1. Ideal for use during routine test and maintenance (e.g. battery test, main board replacement etc). Note, if working on the Mains in the panel you must also follow correct... A high-quality lockable double pole Fire Alarm Control Panel Mains Keyswitch. Allows the Mains...
An optional system expansion device for use with CFP Standard 2-8 Zone Fire Panels or CFP AlarmSense 2-8 Zone Fire Panels. Provides four panel-controlled volt free relay outputs (reset, fault, aux. fire and remote). PCB mounts inside the CFP fire panel. Reset relay is active during the panel’s reset cycle. Fault relay is active in any fault condition.... An optional system expansion device for use with CFP Standard 2-8 Zone Fire Panels or CFP...
An optional system expansion device for use with CFP Standard 2-8 Zone Fire Panels or CFP AlarmSense 2-8 Zone Fire Panels. Provides four panel-controlled volt free relay outputs (reset, fault, aux. fire and remote) and eight output per zone relays. PCB mounts inside the CFP fire panel. Reset relay is active during the panel’s reset cycle. Fault relay... An optional system expansion device for use with CFP Standard 2-8 Zone Fire Panels or CFP...
An optional system expansion device for use with CFP708-4 Standard 8 Zone Fire Panels or CFP708-2 AlarmSense 8 Zone Fire Panels. Provides eight output per zone relays which will changeover when the corresponding zone is in alarm (subject to certain conditions - for full details refer to the instructions, downloadable below). PCB mounts inside the CFP... An optional system expansion device for use with CFP708-4 Standard 8 Zone Fire Panels or CFP708-2...
An optional system expansion device for use with CFP704-4 Standard 4 Zone Fire Panels or CFP704-2 AlarmSense 4 Zone Fire Panels. Provides four output per zone relays which will changeover when the corresponding zone is in alarm (subject to certain conditions - for full details refer to the instructions, downloadable below). PCB mounts inside the CFP... An optional system expansion device for use with CFP704-4 Standard 4 Zone Fire Panels or CFP704-2...
An optional system expansion device for use with CFP702-4 Standard 2 Zone Fire Panels or CFP702-2 AlarmSense 2 Zone Fire Panels. Provides two output per zone relays which will changeover when the corresponding zone is in alarm (subject to certain conditions - for full details refer to the instructions, downloadable below). PCB mounts inside the CFP fire... An optional system expansion device for use with CFP702-4 Standard 2 Zone Fire Panels or CFP702-2...
Compatible with all C-TEC manufactured conventional fire alarm panels. Allows a zone of up to 10 intrinsically safe detectors and any number of manual call points to be used in hazardous environments such as gas plants. Open and short circuit wiring faults on the hazardous side of the barrier shown as open circuit faults at the fire panel. Compatible with all C-TEC manufactured conventional fire alarm panels. Allows a zone of up to...
A spare plastic S-KEY for use C-TEC's CFP, XFP and ZFP fire panels. Provides authorised users with access to a fire panel's authorised user controls. Finished in red polycarbonate for extra strength. See tech. specs below for full panel compatibility details. A spare plastic S-KEY for use C-TEC's CFP, XFP and ZFP fire panels. Provides authorised users...