C-3-8 Addressable Base VAD c/w 96dB(A) Sounder

BF456A/CX/W

New

  • Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by the LPCB.
  • Provides 'C-3-8' light distribution (min 0.4 lux over a 3 x 8m cylindrical area).
  • Supplied with a BF431QCP quick connect plate and detector spur wires.
  • Impressive 96dB(A) sound output @ 1m.
  • Onboard short-circuit loop isolator.
  • 550µA quiescent current.
  • 14mA alarm current @24V DC (VAD lit, sounder on max).
  • Group addressing facility allows multiple devices to be operated simultaneously.
  • 7 selectable volume levels and up to 15 selectable tone pairs.
  • Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
  • IP21C rated.

LPCB CE

By buying this product you can collect up to 27 loyalty points. Your cart will total 27 points that can be converted into a voucher of $5.40.


By buying this product you can collect up to 27 loyalty points. Your cart will total 27 points that can be converted into a voucher of $5.40.


Technical Specifications

Approvals/certifications Certified to EN54-3, 23 & 17 by the LPCB.
Protocol/compatibility Compatible with C-TEC's XFP/ZFP XP95/Discovery Addressable Fire Panels.
Application/operation Designed to be ceiling mounted - either stand-alone with a red or white cap or as part of a stacked Sounder/VAD/Detector Base combination.
VAD category & coverage C-3-8 (15m3 cylindrical coverage).
Flash rate & colour 0.5Hz / White.
Supply/operating voltage 17 to 28V DC (Sounder); 21 to 28V DC (Sounder/VAD).
Quiescent current 550µA @ 24 VDC.
Nominal SPL (Sound Pressure Level) 96dB(A) when set to tone 1.
Alarm current 14mA (VAD lit, Sounder on max).
Indicators Polling (green LED) & Short Circuit Isolator Active (amber LED).
Product dimensions (mm) 122mm diameter x 46mm deep (not including optional XP95/Discovery detector and base).
IP Rating IP21C (Type A).
Weight 170g.
Operating conditions/temperature -10ºC to +55ºC. Max. 95% RH (Non-condensing).

Documentation

14 other products in the same category:

VAD coverage (with multiplication factors applied)

VAD coverage depends on factors such as ambient light and viewing angle (direct or indirect). The table below summarises how the coverage of the BF456A/CX/W increases or decreases based on these factors. To use the table, calculate the lux level of the area requiring coverage, determine whether the viewing angle will be direct or indirect then read off the coverage in the relevant column. For further information refer to our VAD System Design Guide, downloadable from the Documentation tab below.

Lux level in area requiring coverage Ceiling Mounted Direct Viewing Ceiling Mounted Indirect Viewing
000-101 lux 8.3m H x 22.4m W 3.9m H x 10.4m W
101-200 lux 7.2m H x 19.2m H 3.6m H x 9.6m W
201-300 lux 5.7m H x 15.2m W 3.0m H x 8.0m W
301-400 lux 4.2m H x 11.2m W 2.4m H x 6.4m W
401-500 lux 3.3m H x 8.8m W 1.8m H x 4.8m W
501-600 lux 2.7m H x 7.2m W 1.5m H x 4.0m W
601-700 lux 2.1m H x 5.6m W not applicable
701-800 lux 1.5m H x 4.0m W not applicable

BIM/CAD Drawings

BIM Drawing (REVIT)

This file will be uploaded to our website shortly.
Should you need an urgent copy please contact our
marketing team at marketing@c-tec.co.uk

Back to links
Back to links

CAD Drawing (DWG)

This file will be uploaded to our website shortly.
Should you need an urgent copy please contact our