Hi-Output W-2.4-8.2 Wall VAD c/w 103dB(A) Sounder (shallow base) View larger

Hi-Output W-2.4-8.2 Wall VAD c/w 103dB(A) Sounder (deep base)

BF433A/CX/DR

New

  • Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by the LPCB.
  • Provides 'W-2.4-8.2' light distribution when wall mounted (min 0.4 lux over a 2.4m x8.2m cuboid area).
  • Impressive 103dB(A) sound output @ 1m.
  • Onboard short-circuit loop isolator.
  • 550µA quiescent current.
  • 14mA alarm current @24V DC (VAD lit, sounder on max).
  • Group addressing facility allows multiple devices to be operated simultaneously.
  • 7 selectable volume levels and up to 15 selectable tone pairs.
  • IP33C (Type B) rated.

LPCB  CE

By buying this product you can collect up to 27 loyalty points. Your cart will total 27 points that can be converted into a voucher of $5.40.


By buying this product you can collect up to 27 loyalty points. Your cart will total 27 points that can be converted into a voucher of $5.40.


Technical Specifications

Approvals/certificationsCertified to EN54-3, 23 & 17 by the LPCB (0832-CPR-F0945).
Protocol/compatibilityCompatible with C-TEC's XFP/ZFP XP95/Discovery Addressable Fire Panels.
Application/operationDesigned to be wall mounted. IP33C rated and suitable for use outdoors (note an IP65 rated version is also available).
VAD category & coverageW-2.4-8.2 light distribution (min. 0.4 lux over a 2.4m x 8.2m cuboid area). Also certified as a W-4-4 rated VAD.
Flash rate & colour0.5Hz / White.
Supply/operating voltage17 to 28V DC (Sounder); 21 to 28V DC (Sounder/VAD).
Quiescent current550µA @ 24 VDC.
Nominal SPL (Sound Pressure Level)103dB(A) when set to tone 1.
Alarm current14mA (VAD lit, Sounder on max).
IndicatorsPolling (green LED) & Short Circuit Isolator Active (amber LED).
Product dimensions (mm)114mm diameter x 131mm deep.
IP RatingIP33C (Type B).
Weight315g.
Operating conditions/temperature-10ºC to +55ºC. Max. 95% RH (Non-condensing).

Documentation

20 other products in the same category:

VAD coverage (with multiplication factors applied)

VAD coverage depends on factors such as ambient light and viewing angle (direct or indirect). The table below summarises how the coverage of the BF433A/CX/DR increases or decreases based on these factors. To use the table, calculate the lux level of the area requiring coverage, determine whether the viewing angle will be direct or indirect then read off the coverage in the relevant column. For further information refer to our VAD System Design Guide, downloadable from the Documentation tab below.

Lux level in area requiring coverage

W-2.4-8.2 Wall Mounted Direct Viewing

W-2.4-8.2 Wall Mounted Indirect ViewingW-4-4 Wall Mounted Direct ViewingW-4-4 Wall Mounted Indirect Viewing
000-101 lux12.5m H x 42.6m W4.3m H x 14.8m W20.8m H x 20.8m W7.2m H x 7.2m W
101-200 lux10.6m H x 36.1m H4.1m H x 13.9m W17.6m H x 17.6m W6.8m H x 6.8m W
201-300 lux7.7m H x 26.2m W3.4m H x 11.5m W12.8m H x 12.8m W5.6m H x 5.6m W
301-400 lux5.5m H x 18.9m W2.9m H x 9.8m W9.2m H x 9.2m W4.8m H x 4.8m W
401-500 lux4.3m H x 14.8m W2.4m H x 8.2m W7.2m H x 7.2m W4.0m H x 4.0m W
501-600 lux3.1m H x 10.7m W2.1m H x 7.4m W5.2m H x 5.2m W3.6m H x 3.6m W
601-700 lux2.4m H x 8.2m Wnot applicable4.0m H x 4.0m W2.8m H x 2.8m W
701-800 luxnot applicablenot applicable2.8m H x 2.8m Wnot applicable

BIM/CAD Drawings

BIM Drawing (REVIT)

This file will be uploaded to our website shortly.
Should you need an urgent copy please contact our
marketing team at marketing@c-tec.co.uk

Back to links
Back to links

CAD Drawing (DWG)

This file will be uploaded to our website shortly.
Should you need an urgent copy please contact our
marketing team at marketing@c-tec.co.uk

Back to links
Back to links

Approval Certificates

Approval Certificate (LPCB)

Download

EC Certificate of Conformity (CPR)

Download

Declaration of Performance (C-TEC)

Download

Declaration of Conformity (C-TEC)

Download