CAST CA736 Sounder Controller View larger

CAST Sounder Control Module

CA738

New

  • Allows a zone/circuit of conventional fire alarm sounders to be connectedto a CAST protocol fire alarm system.
  • Onboard short circuit loop isolator.
  • Conventional sounder circuit is continually monitored for open and short circuit faults.
  • 3mA typical alarm current (530uA typical quiescent current) @ 22-40V DC.
  • Can provide up to 50mA output current (taken from the CAST addressable loop).
  • Polling, sounder circuit active and sounder circuit fault indicators.

More details

By buying this product you can collect up to 27 loyalty points. Your cart will total 27 points that can be converted into a voucher of $5.40.


By buying this product you can collect up to 27 loyalty points. Your cart will total 27 points that can be converted into a voucher of $5.40.


More Information

'CAST' is the world’s most-advanced 'distributed intelligence’ fire alarm system protocol. Conceived, designed and realised by C-TEC as part of a five-year, multi-million pound project, it involved the creation of a powerful proprietary communication protocol (C-TEC Addressable System Technology, CAST) and multiple control panels & field devices. Now available to purchase, its key features include:

• 255 devices per loop.
• Autonomous decision-making for faster response times.
• Multiple type codes.
• 40V loop drive voltage.
• Two ‘soft’ addressing options – automatic via the panel or manual via a powerful handheld programmer.
• Powerful multi-level addressing facilitates easy device addition and swapped device identification.
• Multiple functionality at a single address (integrated devices) - coming soon.
• Volumes, tones & detector modes can be changed at compatible panels.
• High-speed data transmission and robust data transfer.
• Intrinsically EN54-13 compliant.
• Provides geographical location of short and open circuit faults (a short circuit isolator is included as standard in every CAST field device).
• Replace device function.
• Future seamless integration with other CAST life safety systems reducing energy, servicing, installation and repair costs.
• Designed and manufactured in the UK.

Technical Specifications

Compatibility Compatible with C-TEC's XFP/ZFP CAST Addressable Fire Panels.
Application/operation Allows a zone/circuit of conventional fire alarm sounders and visual alarm devices to be connected to a CAST compatible fire alarm system.
Supply/operating voltage 22-40V DC
Quiescent current 530uA typical.
Zone current Can provide up to 50mA (taken from the CAST addressable loop)
Alarm current 3mA @ 22-40V DC.
Indicators Polling, sounder circuit active and sounder circuit fault indicators.
Product dimensions (mm) 147 W x 87H x 22 D mm. Can be mounted on a standard 25mm UK flush or surface double gang back box.
IP Rating IP40 when correctly installed.
Weight 122g.

Documentation

CAST Sounder Controllers DoC

Declaration of Conformity (EMC / LVD) DOC0000112 Rev 3