Utilising the latest advances in sounder and LED technology, C-TEC's EN54 certified addressable Sounders & VADs (Visual Alarm Devices) are compatible with our entire range of ZFP and XFP XP95/Discovery protocol fire panels. Non-certified VIDS (visual indicators) are also available.
Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by the LPCB. Provides 'C-3-8' light distribution (min 0.4 lux over a 3 x 8m cylindrical area). Supplied with a BF431QCP quick connect plate and detector spur wires. Impressive 96dB(A) sound output @ 1m. Onboard short-circuit loop isolator. 550µA quiescent current. 14mA... Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by the LPCB....
Third-party certified to EN54-3 (Sounders) and 17 (Isolators) by the LPCB. Impressive 96dB(A) sound output @ 1m. Supplied with a BF431QCP quick connect plate and detector spur wires. Onboard short-circuit loop isolator. 550µA quiescent current. 5mA alarm current @24V DC (Sounder on max). Group addressing facility allows multiple devices to be... Third-party certified to EN54-3 (Sounders) and 17 (Isolators) by the LPCB. Impressive 96dB(A)...
Third-party certified to EN54-23 (VADs) and 17 (Isolators) by the LPCB. Provides 'C-3-8' light distribution (min 0.4 lux over a 3 x 8m cylindrical area). Supplied with a BF431QCP quick connect plate and detector spur wires. Onboard short-circuit loop isolator. 550µA quiescent current. 10mA alarm current @24V DC. Group addressing facility allows... Third-party certified to EN54-23 (VADs) and 17 (Isolators) by the LPCB. Provides 'C-3-8' light...
Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by the LPCB. Provides 'W-2.4-8.2' light distribution when wall mounted (min 0.4 lux over a 2.4m x8.2m cuboid area). Impressive 103dB(A) sound output @ 1m. Onboard short-circuit loop isolator. 550µA quiescent current. 14.5mA alarm current @24V DC (VAD lit, sounder on max).... Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by the LPCB....
Third-party certified to EN54-3 (Sounders) and 17 (Isolators) by the LPCB. Impressive 103dB(A) sound output @ 1m. Onboard short-circuit loop isolator. 550µA quiescent current. 5mA alarm current @24V DC (sounder on max). Group addressing facility allows multiple devices to be operated simultaneously. 7 selectable volume levels and up to 15 selectable... Third-party certified to EN54-3 (Sounders) and 17 (Isolators) by the LPCB. Impressive 103dB(A)...
Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by the LPCB. Provides 'W-2.4-8.2' light distribution when wall mounted (min 0.4 lux over a 2.4m x8.2m cuboid area). Impressive 103dB(A) sound output @ 1m. Onboard short-circuit loop isolator. 550µA quiescent current. 14.5mA alarm current @24V DC (VAD lit, sounder on max).... Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by the LPCB....
Third-party certified to EN54-3 (Sounders) and 17 (Isolators) by the LPCB. Impressive 103dB(A) sound output @ 1m. Onboard short-circuit loop isolator. 550µA quiescent current. 5mA alarm current @24V DC (sounder on max). Group addressing facility allows multiple devices to be operated simultaneously. 7 selectable volume levels and up to 15 selectable... Third-party certified to EN54-3 (Sounders) and 17 (Isolators) by the LPCB. Impressive 103dB(A)...
An IP55 version of our popular W.2.4-8.2 Wall VAD & Sounder. Provides 'W-2.4-8.2' light distribution when wall mounted (min 0.4 lux over a 2.4m x8.2m cuboid area) using the same lens and electonics as our EN54-23, 3 & 17 certified Hi-Output Sounder VAD. Impressive 103dB(A) sound output @ 1m. Onboard short-circuit loop isolator. 550µA quiescent... An IP55 version of our popular W.2.4-8.2 Wall VAD & Sounder. Provides 'W-2.4-8.2' light...
Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek. Provides 'C-3-8' light distribution when ceiling mounted (min 0.4 lux over a 3 x 8m cylindrical area). Can also provide 'W-3-3.1' light distribution when wall mounted (min. 0.4 lux over a 3 x 3.1m cuboid area). Impressive 91dB(A) sound output @ 1m. Onboard... Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek....
Third-party certified to EN54-3 (Sounders) and 17 (Isolators) by Intertek. Impressive 91dB(A) sound output @ 1m. Onboard short-circuit loop isolator. 550µA quiescent current. 5mA alarm current @24V DC (VAD lit, sounder on max). Group addressing facility allows multiple devices to be operated simultaneously. 7 selectable volume levels and up to 15... Third-party certified to EN54-3 (Sounders) and 17 (Isolators) by Intertek. Impressive 91dB(A)...
Third-party certified to EN54-23 (VADs) and 17 (Isolators) by Intertek. Provides 'C-3-8' light distribution when ceiling mounted (min 0.4 lux over a 3 x 8m cylindrical area). Can also provide 'W-3-3.1' light distribution when wall mounted (min. 0.4 lux over a 2.4 x 3.5m cuboid area). Onboard short-circuit loop isolator. 550µA quiescent current. 10mA... Third-party certified to EN54-23 (VADs) and 17 (Isolators) by Intertek. Provides 'C-3-8' light...
Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek. Provides 'W-3-3.1' light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area). Can also provide 'C-3-8' light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area). Impressive 91dB(A) sound output @ 1m. Onboard... Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek....