ActiV W-2.75-9 Weatherproof Wall VAD c/w Voice Sounder View larger

ActiV Conventional Weatherproof Hi-Output W-2.75-9 Wall VAD c/w Voice Sounder (IP55)

BF447C/CC/DR/65

New

  • Provides 'W-2.75-9' rated light distribution when wall mounted (min. 0.4 lux over a 2.75 x 9m cuboid area). Can also be used as a W-4-4 VAD.
  • Superb sound intelligibility.
  • Choose from two evacuation voice messages and four evacuation alarm tones (your selected evacuation message will be preceded by the selected tone).
  • Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
  • Alarm Current at 30Vdc = 17mA (0.5Hz) or 24mA (1Hz)
  • Alarm Current at 18Vdc = 18.5mA (0.5Hz) or 30mA (1Hz)
  • IP55C rated (weatherproof).
  • Manufactured in the UK by C-TEC.

By buying this product you can collect up to 27 loyalty points. Your cart will total 27 points that can be converted into a voucher of $5.40.


By buying this product you can collect up to 27 loyalty points. Your cart will total 27 points that can be converted into a voucher of $5.40.


Technical Specifications

Protocol/compatibilityCompatible with C-TEC's CFP, FP, MFP and EP203 conventional fire alarm panels and virtually all other makes (testing on third-party panels is recommended before use)
Application/operationDesigned to be wall mounted. Can be used in covered outdoor areas.
VAD category & coverageW-2.75-9 rated light distribution (min. 0.4 lux over a 2.7.5m x 9m cuboid area). Can also be used as a W-4-4 VAD.
Flash rate & colour0.5Hz; 1Hz or OFF / White.
Supply/operating voltage18 to 30V DC.
Alarm currentAt 30Vdc: 17mA (0.5Hz) or 24mA (1Hz); At 18Vdc: 18.5mA (0.5Hz) or 30mA (1Hz)
Product dimensions (mm)114mm diameter x 132mm deep.
IP RatingIP55C (Weatherproof).
Weight315g.
Operating conditions/temperature-10ºC to +55ºC. Max. 95% RH (Non-condensing).

Documentation

8 other products in the same category:

VAD coverage (with multiplication factors applied)

VAD coverage depends on factors such as ambient light and viewing angle (direct or indirect). The table below summarises how the coverage of the BF447C/CC/DR/65 increases or decreases based on these factors. To use the table, calculate the lux level of the area requiring coverage, determine whether the viewing angle will be direct or indirect then read off the coverage in the relevant column. For further information refer to our VAD System Design Guide, downloadable from the Documentation tab below.

 Wall MountedWallMounted
Lux level in area requiring coverageDirect ViewingIndirect Viewing
000-101 lux14.30m H x 46.80m W4.95m H x 16.2m W
101-200 lux12.10m H x 39.60m W4.67m H x 15.3m W
201-300 lux8.80m H x 28.80m W3.85m H x 12.6m W
301-400 lux6.32m H x 20.70m W3.30m H x 10.8m W
401-500 lux4.95m H x 14.40m W2.75m H x 9m W
501-600 lux3.57m H x 11.7m W2.47m H x 8.1m W
601-700 lux2.75m H x 9.0m W1.92m H x 6.3m W
701-800 lux1.90m H x 6.3W1.65m H x 5.4m W