  • A high-quality remote LED indicator specifically designed for use in fire alarm systems. Incorporates a high intensity, wide-angle red LED which is clearly visible from the front of the plate when active. Ideal for indicating the activation of hidden or out of-sight fire detectors, etc. Includes a white ‘write on’ area allowing installers to add... A high-quality remote LED indicator specifically designed for use in fire alarm systems....

  • A general purpose, double-pole, polarised 24V 5A relay designed for use in 24V fire alarm systems. Incorporates a high intensity LED which illuminates red when the relay is active. Can be connected to a suitable control panel relay output or a standard polarised fire alarm sounder circuit to operate door retaining magnets, rollershutter doors, etc. Can... A general purpose, double-pole, polarised 24V 5A relay designed for use in 24V fire alarm...

  • A 24V 5A polarised relay designed for use in 24V fire alarm systems. Includes a keyswitch isolation facility allowing the relay operation to be temporarily disabled during routine test and maintenance to prevent autodiallers, water sprinklers, rollershutters, etc., from activating. When isolated, the unit's Isolated LED will flash and a warning beeper... A 24V 5A polarised relay designed for use in 24V fire alarm systems. Includes a keyswitch...

  • Allows a +24 VDC output from a fire alarm control panel to be remotely isolated to prevent autodiallers, water sprinklers, rollershutters, etc., from activating. Designed so that if monitoring is used on the +24 VDC output being controlled, a fault condition will show at the fire panel when the device is Isolated. Label includes a white ‘write on’ area... Allows a +24 VDC output from a fire alarm control panel to be remotely isolated to prevent...

  • Provides four extra conventional sounder circuits with open and short circuit fault monitoring. Compatible with most manufacturers' fire alarm control panels. Supplied on a double gang plate.  Basic connection requires four wires: 24 VDC, 0V, Sounder –Ve & Sounder +Ve. Sounder -Ve & Sounder +Ve can be connected at the host panel or any convenient... Provides four extra conventional sounder circuits with open and short circuit fault monitoring....

  • Provides early warning of a potential fire alarm condition to the hard of hearing. Connects to a standard 24V DC conventional fire alarm sounder circuit via a separately-available BF363 Single Gang Locking Jack Socket. Typically used under pillows in hotel bedrooms, etc. Includes a 2m connection lead (users are advised to leave a minimum amount of the... Provides early warning of a potential fire alarm condition to the hard of hearing. Connects to a...

  • Allows the BF363 Vibrating Pillow Pad to be connected to a 24V DC conventional fire alarm sounder circuit. Typically used to provide early warning of a potential fire alarm condition to the hard of hearing. Max. operating voltage 27V DC. Mounts on a standard UK 18mm single gang flush or surface back box. Includes Braille text. Allows the BF363 Vibrating Pillow Pad to be connected to a 24V DC conventional fire alarm sounder...

  • A light grey keyswitch lockable enclosure ideal for storing important documentation relating to your fire alarm, voice alarm, disabled refuge, nursecall and other life safety applications. Attractively designed in mild steel to match the style, colour and finish of virtually all of C-TEC's fire and nursecall ranges. Can securely house the mandatory site... A light grey keyswitch lockable enclosure ideal for storing important documentation relating to...

  • Designed to meet requirement 17.9.2c of Dutch standard NEN2575. BSI certified to EN54 parts 17 & 18. Easily interfaced to a conventional fire alarm sounder circuit. Allows low-cost, non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365IM Isolator Modules (subject to fire officer approval).  Wiring must be made... Designed to meet requirement 17.9.2c of Dutch standard NEN2575. BSI certified to EN54 parts 17 &...

  • A fault isolating module with sounder drive capability designed to meet requirement 17.9.2c of Dutch standard NEN2575. BSI certified to EN54 parts 17 & 18. Measures just 55mm x 55mm x 16mm (will fit in the base of most conventional sounders). Up to 30 BF365IM modules per BF365SC controller. Allows low-cost, non-fire resistant sounder circuit cabling... A fault isolating module with sounder drive capability designed to meet requirement 17.9.2c of...

Showing 1 - 10 of 10 items